s890ql1/s890ql-1/high strength/extra toughness

S890QL1 Quenched and Tempered Structural Steel

S890QL1 Mechanical Properties

Plate thickness

Minimum Yield

Strength

Minimum Tensile Strength

Minimum Elongation

mm [inches] 1)

ReH2) MPa [ksi] 1)

Rm MPa [ksi]1)

A5%

Minimum

A2in.3)%

Minimum

≤ 50mm [2inches]

890MPa [130ksi]

940~1100 [136~159ksi]

12

13

> 50mm [2inches]

≤ 80mm [3inches]

850 MPa [123ksi]

900~1100 [130~159ksi]

12

13

> 80mm [3inches]

≤ 100mm [4inches]

830 MPa [120ksi]

880~1100 [128~159ksi]

12

13

Higher minimum values may be agreed on request.

S890QL1 V Notch Impact Test

Position of Samples

Impact energy Av Joules [ft-lb]1) at test temperature

0ºC [32ºF] 1)

-20ºC [-4ºF] 1)

-40ºC [-40ºF] 1)

-60ºC [-76ºF] 1)

Longitudinal

60 Joules [44]

50 Joules [37]

40 Joules [30]

30 Joules [22]

Transverse

40 Joules [30]

35 Joules [26]

30 Joules [22]

27Joules[20]

The specified minimum value is the get real health and fitness average of 3 tests. Only one individual value is

permitted to be below this minimum value, and no more than 30%. For plate thicknesses below 12 mm, the test can be carried out on Premiers Signes impuissance chez les hommes Buy Cialis Charpy-V test specimens with reduced width; the minimum width must be 5 mm. The minimum impact value will be decreased proportionally.

1) The Values are for information only.

2) if not apparent, the yield strength Rp0.2 is measured instead.

3) These values apply if tested according to ASTM A370.

 EN10025 S890QL1 Extra High Strength and Toughness Steel Plate